0 item(s)

Battery Charger 12V 50A Phoenix Smart IP43 Victron

Battery Charger 12V 50A

  • 210 – 250 Vac input ; 290 – 355 VDC input
  • Operating voltage: 12Vdc
  • Charging current: 50А
  • IP43 (electronic components), IP22 (connection area)
  • 2 outputs- the second output 3A is for a starter battery

SKU: PSC125051085
1073 €547.23 VAT included

Availability: Backorder

Delivery time: 8-15 days

Quantity:

Bluetooth Smart enabled 

Any Bluetooth enabled smart phone, tablet or other device can be used to monitor, to change settings and to update the charger when new software features become available

PhoenixSmart(1+1): two outputs to charge 2 battery banks

The second output, limited to approximately 3A and with a slightly lower output voltage, is intended to top up a starter battery.

Automatic voltage compensation

The charger compensates for voltage drop over the DC cabling by slightly increasing output voltage when the DC current increases. Please see the manual for details.

Adaptive 5-stage chargealgorithm: bulk absorption reconditionfloat storage

The Phoenix Smart Charger features our well-known ‘adaptive’ battery management system that can be preset to suit different types of batteries. The ‘adaptive’ feature will automatically optimise the charge process relative to the way the battery is being used.

The right amount of charge: variable absorption time

When only shallow discharges occur (a yacht connected to shore power for example) the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery will be fully charged

Preventing damage due to excessive gassing: the BatterySafe mode (see fig. 2)

If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the charger will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached (see the charge curve between 14,4 V and 15,0 V in fig. 2).

Less maintenance and aging when the batteryis not in use: the Storage Mode (see fig. 1 & 2)

The Storage Mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the Storage Mode float voltage is reduced to 2,2 V/cell (13,2 V for a 12 V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘equalize’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure.

Also charges Li-ion (LiFePO) batteries

Charger on-off control can be implemented by connecting a relay or open collector optocoupler output from a Li-ion BMS to the remote on-off port.Alternatively full control of voltage and current can be achieved with Bluetooth.

Fully programmable charge algorithm

The charge algorithm can be programmed with help of Bluetooth or the VE.Direct interface.Three preprogrammed algorithms can be selected with the mode button (see specifications).

Remote on-off

The remote on/off consists of two terminals: Remote H and Remote L.A remote on/off switch or relay contact can be connected between H and L.Alternatively, terminal H can be pulled high, or terminal L can be pulled low.

VE.Direct interface

For a wired data connection to a Color Control panel, PC or other devices. Please see the VictronConnect app under Downloads / Software on our website.

Programmable relay

Can be programmed using the VE.Direct interface or a Bluetooth enabled deviceto trip on an alarm or other events.

 

 

Input voltage 230 VAC (range: 210 – 250 V)
DC input voltage range 290 – 355 VD
Frequency 45 - 65 Hz
Back current drain AC disconnected: < 0,1 mA AC connected and charger remote off: < 6 mA
No load power consumption 1 W
Efficiency 94%
Charge voltage 'absorption' Normal: 14,4V High: 14,7V Li-ion: 14,2V
Charge voltage 'float' Normal: 13,8V High: 13,8V Li-ion: 13,5V
Storage mode Normal: 13,2V High: 13,2V Li-ion: 13,5V
Charge current house battery 50A
Low current mode 25A
Charge current starter battery
Charge algorithm 5 stage adaptive
Protection Battery reverse polarity (fuse, not user accessible) / Output short circuit / Over temperature
Can be used as power supply Yes, output voltage can be set with Bluetooth and/or VE.Direct
Operating temp. range -20 to 60°C (0 -140°F)Rated output current up to 40°C, derate linearly to 20% at 60°C
Humidity (non-condensing) max 95%
Relay (programmable) DC rating: 5 A up to 28 VDC
Battery-connection Screw terminals 16 mm² (AWG6)
AC-connection IEC 320 C14 inlet with retainer clip (AC cord with country specific plug must be ordered separately)
Protection category IP43 (electronic components), IP22 (connection area)
Weight kg
3,5 kg
Dimensions (hxwxd) 180 x 249 x 100 mm
STANDARDS  
Safety EN 60335-1, EN 60335-2-29
Emission EN 55014-1, EN 61000-3-2, EN 61000-6-3
Immunity EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Vibration EC68-2-6:10-150Hz/1.0G
View FileТехнически данни / Datasheet    File size: (333.65 KB)
View FileПредставителство на ф.Чепъков за България    File size: (326.95 KB)