0 item(s)

Inverter RS Smart Solar48/6000

Output             Full sine wave
Nominal power at 250C
    6000VA / 4800W
Peak power at 250C
    6000W
Warranty of the producer     5 years
Battery voltage
    48Vdc

SKU: PIN482601000
4231 €2,157.81 VAT included

Availability: Backorder

Delivery time: 15-20 days

Quantity:

 

Off-Grid solar inverter

The Inverter RS Smart Solar 48/6000 is a 48V 6kVA Inverter with 450VDC 4kWp PV input. It is used in off-grid solar applications where AC power is required.

Combination of aninverter, bi-directional DC-DC converterand MPPT

The inverter produces a perfect sine wave, able to supply high powered appliances. It is supplied by a bi-directional DC-DC converter, that can either charge the battery when excess solar power is available or convert from the battery when it is needed

Wide MPPT voltage range

80 – 450VDC, with a 120VDC PV startup voltage

Light weight, efficient and quiet

Thanks to high frequency technology and a new design this powerful inverter weighs only 11kg. In addition to this it has an excellent efficiency, low standby power, and a very quiet operation

Display and Bluetooth

 

The display reads battery, inverter and solar charge controller parameters.The same parameters can be accessed with a smartphone or other Bluetooth enabled device. In addition, Bluetooth can be used to set up the system and to change settings with VictronConnect.

Displ

 VE.Canand VE.Directport

For connection to a GX device for system monitoring, data logging, and remote firmware updates.

 

Built in PV isolator

Both parallel PV strings connected to the MC4 plugs can be safely isolated with the large built-in switch on the bottom of the unit.

I/O Connections

Programmable Relay, temperature sensor and voltage sensor connections. The remote input can also be configured to accept the Victron miniBMS.

 

Inverter RS Smart Solar 48/6000
INVERTER  
DC Input voltage range 38 -64V (6)
Output Output voltage: 230 VAC ± 2%Frequency: 50 Hz ± 0.1% (1)
Continuous output power at 25°C Increases linearly from 4800 W at 46 VDCto 5300 W at 52 VDC
Continuousoutput power at 40°C 4500W
Continuousoutput power at 65°C 3000W
Peak power 9kW for 3 seconds
Short-circuit output current 50A
Maximum efficiency 96.5% at 1kW load 94% at 5kW load
Zero load power 20W
SOLAR  
Maximum DC voltage 450V
Nominal DC voltage 300V
Start-up voltage 120V
MPPT operating voltage range 80 450V (5)
DC input current limit 18A (4)
Maximum DC input current 20A
Maximum PV input power 4000W
Maximum DC charging power 4000W
Earth leakage trip level 30 mA
CHARGER  
 Charge voltage 'absorption' (V DC)  57.6V
 Charge voltage 'float' (V DC)  55.2V
 Maximum charge current  100A
 Battery temperature sensor  Yes
 GENERAL  
 Parallel and 3-phase operation No
 Programmable relay (3)
 Yes
 Protection (2)  a -f
 Data Communications Ports  VE.Direct port and VE.Can port
 General purpose analogue/digital in port  Yes, 2x
 Remote on-off  Yes
 Operating temperature range  -40 to +65°C (fan assisted cooling)
 Humidity (non-condensing)  max 95%
 ENCLOSURE  
 Material & Colour  steel, blue RAL 5012
 Protection category  IP21
 Battery-connection  M8 bolts
 230 V AC-connection  Screw terminals 13 mm²(6 AWG)
 Weight  11 kg
 Dimensions (hxwxd)  425 x 440 x 125 mm
 STANDARDS  
Safety EN-IEC 60335-1, EN-IEC 60335-2-29,EN-IEC 62109-1, EN-IEC 62109-2
 Emission, Immunity  EN 55014-1, EN 55014-2EN-IEC 61000-3-2, EN-IEC 61000-3-3 IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
  1. Can be adjusted to 60 Hz.
  2. Protection key: a) output short circuit. b) overload. c) battery voltage too high. d) battery voltage too low. e) temperature too high. f) 230 VAC on inverter output
  3. Programmable relay which can be set for general alarm, DC under voltage or genset start/stop function. DC rating: 4A up to 35VDC and 1A up to 70VDC
  4. Normal operation is regulated to 18A, with maximum reverse polarity protection 20A
  5. MPPT operating range is also constrained by battery voltage - PV VOC should not exceed 8x battery float voltage, e.g. a 50V battery voltage maximum should have 400V maximum PV array.– see product manual for further information.
  6. Minimum start-up voltage is 41V. Inverter shutdown can be set as low as 32V DC, but may shut down on low AC output voltage (due to load). Over-voltage disconnect is 65.5V. Charger set-point can be set to max 62V. The charge current derates above 57V.
View FileISO9001-certificate-2018    File size: (655.53 KB)
View FileТехнически данни (Английски) / Datasheet    File size: (435.22 KB)
View FileСЕ Декларация    File size: (26.71 KB)
View FileПредставителство на ф.Чепъков за България    File size: (326.95 KB)