Isolation Transformer 3600W Auto 115V - 230V/32A-16A Victron

The Isolation Transformer eliminates any electrical continuity between AC shore power and the boat. It is essential for safety and eliminates the need for galvanic isolators and polarity alarm

Input:  115 / 230V

Output: 115 / 230V

Frequency:  50/60 Hz

Rating: 32/16 A

Soft start: Yes


SKU: ITR050362041
1499 €764.49 VAT included

Availability: Backorder

Delivery time: 8-15 days

Quantity:

Safety and prevention of galvanic corrosion

The Isolation Transformer eliminates any electrical continuity between AC shore power and the boat. It is essential for safety and eliminates the need for galvanic isolators and polarity alarm

Safety is taken for granted in case of a normal on- shore installation. A fuse will blow or a GFCI (Ground Fault Current Interrupter) will trip in case of a short circuit or current leakage to ground. Connecting the ground wire of the shore -side supply to the metal parts of the boat will result in galvanic corrosion (see below). Bringing only the live a nd neutral wire on board results in a n unsafe situation because GFCI s will not work nor will a fuse blow in case of a short circuit to a metal part on the boat.

Galvanic corrosion occurs when two dissimilar metals in electrical contact are simultaneously exposed to an electrically conducting fluid. Seawater and, to a lesser extent, fresh water are such fluids. In general, the more active alloy of the couple corrodes preferentially while the less active (more noble) material is cathodically protected. The r ate of galvanic corrosion is a function of several variables including area ratios, conductivity of the fluid, temperature, nature of the materials, etc.

It is a misunderstanding that galvanic corrosion occurs only in metal and aluminium hulls. In fact i t can occur on any boat as soon as a metallic part (the shaft and propeller) is in contact with water. Galvanic corrosion will quickly dissolve your sacrificial anodes, and attack the shaft, propeller and other metal parts in contact with water as soon as the boat is connected to the shore- side supply. It might therefore be tempting not to connect the ground conductor: this is however extremely dangerous because GFCI s will not work nor will a fuse blow in case of a short circuit to a metal part on the boat

The best solution to avoid galvanic corrosion and at the same time prevent any uns afe situation is to install an Isolation T ransformer to connect to the shore- side supply. The Isolation T ransformer eliminates any electrical continuity between shore pow er and the boat. The shore power is fed to the primary side of the transformer and the ship is connected to the secondary. The I solation Transformer completely isolates the boat from the shore ground. By connecting all metal parts to the neutral output on the secondary side of the transformer, a GFCI will trip or a fuse will blow in case of a short circuit.

Soft start is a standard feature of a Victron Energy isolation transformer. It will prevent the shore power fuse from blowing due to the inrush current of the transformer, which would otherwise occur

It is also recommended , for optimal safety, to connect the secondary neutral of the transformer to ground when the boat is out of the water.

Technical Data:

Input:  115 / 230V

Output: 115 / 230V

Frequency:  50/60 Hz

Rating: 32/16 A

Soft start: Yes

Transformer type: Toroidal

Input circuit breaker: Yes

View FileТехнически данни (Aнглийски) / Datasheet    File size: (261.38 KB)