0 item(s)

Victron Charger Skylla-IP65 12V / 70A (1+1)

  • 70А charging current
  • Input voltage: 90-265Vac.
  • Protection level - IP65

SKU: SKY012070000
1803 €919.53 VAT included

Availability: Backorder

Delivery time: 15-20 days

Quantity:

Тwo outputs to charge 2 battery banks

The Skylla-IP65 (1+1) features 2 isolated outputs. The second output, limited to approximately 3A and with
a slightly lower output voltage, is intended to top up a starter battery.

IP65 protection

Steel epoxy powder coated case and splash proof. Withstands the rigors of an adverse environment: heat,
humidity and salt air.
Circuit boards are protected with an acrylic coating for maximum corrosion resistance.
Temperature sensors ensure that power components will always operate within specified limits, if needed
by automatic reduction of output current under extreme environmental conditions.

LCD display

For status monitoring and to easily adapt the charge algorithm to a particular battery and its conditions of
use.

CAN bus interface (NMEA2000)

To connect to a CAN bus network, to a Skylla-i Control panel or to the Color Control digital display.

Synchronised parallel operation

Several chargers can be connected in parallel and synchronised with help of the CAN bus interface. This is
achieved by simply interconnecting the chargers with RJ45 UTP-cables.

The right amount of charge for a lead-acid battery: variable absorption time

When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of
the battery. After a deep discharge the absorption time is automatically increased to make sure that the
battery is completely recharged.

Preventing damage due to excessive gassing: the BatterySafe mode

If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage
has been chosen, the Skylla-IP44 will prevent damage due to excessive gassing by automatically limiting
the rate of voltage increase once the gassing voltage has been reached.

Less maintenance and aging when the battery is not in use: the Storage mode

The Storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In
the storage mode float voltage is reduced to 2,2V/cell (26,4V for 24V battery) to minimise gassing and
corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’
the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early
battery failure.

To increase battery life: temperature compensation

Every Skylla-IP65 comes with a battery temperature sensor. When connected, charge voltage will
automatically decrease with increasing battery temperature. This feature is especially recommended for
sealed lead-acid batteries and/or when important fluctuations of battery temperature are expected.

Battery voltage sense

In order to compensate for voltage loss due to cable resistance, the Skylla-IP44 is provided with a voltage
sense facility so that the battery always receives the correct charge voltage.

Use as a power supply

As a result of the excellent control circuit, the Skylla-IP44 can be used as a power supply with perfectly
stabilized output voltage if batteries or large buffer capacitors are not available.

Li-Ion (LiFePO4) ready

Simple charger on-off control can be implemented by connecting a relay or open collector opto coupler
output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of
voltage and current can be achieved by connecting to the CAN bus port.

View FileISO9001-certificate-2018    File size: (655.53 KB)
View FileТехнически данни (Английски) / Datasheet    File size: (280.1 KB)