0 item(s)

Inverter FRONIUS Tauro 50-3-D 50kW

Three-phase 50 kW invertor with 3 MPP trackers.

IP 65 protection class

 


SKU: tauro-50-3-d
14180 €7,231.80 VAT included

Availability: Backorder

Delivery time: 8-30 days

Quantity:

Smart hardware design

The three-phase Fronius Tauro in the 50 kW power class promises maximum performance, even under the harshest conditions. It not only contributes to BOS cost optimization, but also offers unprecedented flexibility in system design. The Fronius Tauro can be used to implement sophisticated roofs in both centralised (P variant) and decentralised system designs (D variant). Simplest installation and the fastest service on the market also guarantee maximum safety.

DATA

INPUT

Number of MPP trackers 3
Max. input current (Idc max_inverter) 134 A
DC input voltage range (Udc min - Udc max) 200 - 1000 V
Feed-in start voltage (Udc start) 200 V
MPP voltage range (Umpp min - Umpp max) 400 - 870 V
Max. PV generator power (Pdc max 75 kWpeak
Max. input current PV1 (Idc max, PV1) 36 A
Max. input current PV2 (Idc max, PV2) 36 A
Max. input current PV3 (Idc max, PV3) 72 A
Max. short-circuit current PV1 (Isc max, PV1) 72 A
Max. short-circuit current PV2 (Isc max, PV2) 72 A
Max. short-circuit current PV3 (Isc max, PV3) 125 A
Max. short-circuit current inverter (Isc max, inverter) 240 A
Max. input current string (Idc max, String) 14,5 A
Max. short-circuit current string (Isc max, string) 20 A
Max. power PV system PV1 (Pdc max,PV1) 25 kWpeak
Max. power PV system PV2 (Pdc max, PV2) 25 kWpeak
Max. power PV system PV3 (Pdc max, PV3) 50 kWpeak
Number of DC connections PV1 4
Number of DC connections PV2 3
Number of DC connections PV3 7
Max. AC fuse size rating 355 A

OUTPUT

AC nominal output (Pac,r) 50 kW
Max. output power (Pac max) 50 kVA
AC output current (Iac nom) 75.8A at 220Vac, 72.5A at 230Vac
Grid connection (Uac,r) 3~ NPE 380/220 , 3~ NPE 400/230 V
AC voltage range (Umin - Umax) 180 - 270 V
Frequency (fr) 50/60 Hz
Frequency range (fmin - fmax) 45 - 65 Hz
Total harmonic distortion <3,0%
Power factor (cos φac,r) 1 ind,/cap,
Max. DC fuse size rating 20 A

GENERAL

Length 1109 mm
Width 755 mm
Depth 346,2 mm
Weight incl. packaging 111 kg
Degree of protection IP65
Protection class 1
Overvoltage category (DC / AC) 1) 2 / 3
Night-time consumption 15 W
Installation Indoor and outdoor 4)
Ambient temperature range '-40°C - +65°C (optional AC-disconnect: from - 30 to + 65 °C) 
Permitted humidity 0-100 %
Max. altitude 2) 4000 m
Certificates and compliance with standards VDE-AR-N 4105, VDE-AR-N 4110, IEC 62109-1/-2, IEC 62116, IEC 61727 R25, AS/NZS 4777, CEI 0-16, CEI 0-21, EN 50549-1/-2, VDE 0126-1-1*
Inverter topology Transformerless
Cooling Active Cooling Technologie and Double-Wall System
Interference emission class B

EFFICIENCY

Max. efficiency (PV - grid) 98,5 %
European efficiency (ηEU) 97,8 / 98,3 / 97,9 / 97,7 (400Vdc / 600Vdc / 800Vdc / 870Vdc)
η at 5% Pac,r 3) 94,90 / 96,52 / 92,87 / 91,80 (400Vdc / 600Vdc / 800Vdc / 870Vdc)
η at 10% Pac,r 3) 97,33 / 97,91 / 96,54 / 95,68 ((400Vdc / 600Vdc / 800Vdc / 870Vdc)
η at 20% Pac,r 3) 98,04 / 98,45 / 97,90 / 97,63 (400Vdc / 600Vdc / 800Vdc / 870Vdc)
η at 25% Pac,r 3) 97,86 / 98,44 / 98,07 / 97,88 (400Vdc / 600Vdc / 800Vdc / 870Vdc)
η at 30% Pac,r 3) 97,92 / 98,51 / 98,14 / 98,05 (400Vdc / 600Vdc / 800Vdc / 870Vdc)
η at 50% Pac,r 3) 97,99 / 98,48 / 98,24 / 98,17 (400Vdc / 600Vdc / 800Vdc / 870Vdc)
η at 75% Pac,r 3) 97,86 / 98,35 / 98,17 / 98,10 (400Vdc / 600Vdc / 800Vdc / 870Vdc)
η at 100% Pac,r 3) 97,63 / 98,16 / 98,04 / 97,99 (400Vdc / 600Vdc / 800Vdc / 870Vdc)

PROTECTION DEVICES

DC insulation measurement Included
Overload behaviour Operating point shift. Power limitation 5)
DC disconnector Included
DC Reverse polarity protection Included
Integral RCMU Included
Overvoltage protection devices Type 1 + 2 integrated, Type 2 optional 6)
DC string fusing integrated, 15 A or 20 A

INTERFACES

6x digital in/out + 6x digital in Programmable interface for ripple control receiver, energy management, load control (Inputs: Voltage level low: min. 0V - max. 1.8V; high: min. 4,5V - max. 28,8V / Input resistance: 70kOhm
Outputs: 5 Watt @ 12V in total for all six digital outputs when supplied internally in case of no load on the USB Port.
1A @ >12,5V to 24V per digital output when supplied externally by an external power supply but in total max. 3A)
Emergency stop (WSD) Yes
Datalogger and web server Included 7)
WLAN Fronius Solar.web, Modus TCP Sunspec, Fronius Solar API (JSON)
2x RS485 Modbus RTU Sunspec
USB (type A socket) 1 A supply
Ethernet LAN RJ45 10/100Mbit; max. 100m Fronius Solar.web, Modbus TCP Sunspec, Fronius Solar API (JSON) 7)

AC CONNECTION TECHNOLOGY

Cable cross section 35 - 240 mm²
Conductor material Al; Cu
Connection terminals Cable lug or V clamps
Single core option (single core cable) Cable gland: 5 x M40 (10 - 28 mm)
Multi core option (multi core cable) Cable gland: 1 x multi core connection Ø 16 - 61.4 mm + 1 x M32 (10 - 25 mm)
AC Daisy Chaining option (single core cable) Cable gland: 10 x M32 (10 - 25 mm)

DC CONNECTION TECHNOLOGY

Cable cross section 4 - 6 mm²
Conductor material Cu
Connection terminals DC direct connection, Stäubli Multi Contact MC4

FOOTNOTES FOR TECHNICAL DATA

1) According to IEC 62109-1  

2) Unrestricted voltage range

3) At 580Vdc / 800Vdc / 930Vdc

4) Direct in the sun is possible

5) At an ambient temperature of 50°C

6) AC-, DC-Overvoltage protection

7) An Ethernet star-configuration is used for communication with multiple inverters. Each individual inverter communicates independently with the network/Internet via its integrated data logger