The HUAWEI SUN2000-50KTL-M3 is known for its high efficiency, reliable performance, and advanced safety features. It has a maximum efficiency of 98.6%, and its smart cooling system ensures optimal performance even in high-temperature environments. It also has built-in surge protection and ground fault detection to ensure safe and reliable operation.
The inverter offers a wide range of benefits for solar project developers and owners. These include improved energy yield, reduced maintenance costs, and easy installation and commissioning. Its modular design also allows for flexible configuration and expansion as needed.
The HUAWEI 50KTL has a maximum input voltage of 1100V and a maximum output power of 50 kW. It is compatible with both monocrystalline and polycrystalline solar panels, and it can be installed both indoors and outdoors.
The HUAWEI SUN2000-50KTL-M3 is an excellent choice for large-scale solar projects that require high efficiency, reliability, and safety. With its advanced features, flexible configuration, and easy installation, it is sure to provide long-term value and performance.
EFFICIENCY |
|
Max. Efficiency | 98.50% |
European Efficiency | 98.00% |
INPUT DATA |
|
Max. Input Voltage 1 | 1,100 V |
Max. Current per MPPT | 30 A |
Max. Short Circuit Current per MPPT | 40 A |
Start Voltage | 200 V |
MPPT Operating Voltage Range 2 | 200 V ~ 1,000 V |
Rated Input Voltage | 600 V |
Number of MPP trackers | 8 |
Max. input number per MPP tracker | 4 |
OUTPUT DATA |
|
Rated AC Active Power | 50,000 W |
Max. AC Apparent Power | 55,000 VA |
Rated Output Voltage | 400Vac/480Vac,3W+(N) +PE |
Rated AC Grid Frequency | 50 Hz / 60 Hz |
Rated Output Current | 72,2 A |
Max. Output Current | 79,8 A |
Adjustable Power Factor Range | 0.8 leading... 0.8 lagging |
Max. Total Harmonic Distortion | <3% |
PROTECTIONS |
|
Input-side Disconnection Device | Yes |
Anti-islanding Protection | Yes |
AC Overcurrent Protection | Yes |
DC Reverse-polarity Protection | Yes |
PV-array String Fault Monitoring | Yes |
DC Surge Arrester | Type II |
AC Surge Arrester | Type II |
DC Insulation Resistance Detection | Yes |
Residual Current Monitoring Unit | Yes |
Communication | |
Display | LED indicators; Integrated WLAN + FusionSolarAPP |
RS485 | Yes |
Monitoring BUS (MBUS) | Yes (isolation transformer required) |
GENERAL DATA |
|
Dimensions (height x width x depth) |
640 x 530 x 270 mm |
Weight | 49 kg |
Degree of protection | IP 66 |
Night time consumption | < 5.5 W |
Inverter design | Transformerless |
Cooling | Natural Convection |
Installation | Indoor and outdoor installation |
Ambient temperature range | -25°C to +60°C |
Permitted humidity | 0 % to 100 % |
Max, altitude | 4000 m |
DC connection technology | Staubli MC4 |
AC connection technology | Waterproof PG Terminal + OT/DT Terminal |
Certificates Grid Code |
EN 62109-1/-2, IEC 62109-1/-2, EN 50530, IEC 62116, IEC 60068, IEC 61683 IEC 61727, VDE-AR-N4105, VDE 0126-1-1, BDEW, G59/3, UTE C 15-712-1, CEI 0-16, CEI 0-21, RD 661, RD 1699, P.O. 12.3,RD 413, EN-50438-Turkey, EN-50438-Ireland, C10/11, MEA, Resolution No.7, NRS 097-2-1, AS/NZS 4777.2, DEWA |
1. The maximum input voltage is the upper limit of the DC voltage. Any higher input DC voltage would probably damage inverter.
2. Any DC input voltage beyond the operating voltage range may result in inverter improper operating.
SUN2000-30~40KTL-M3 raises potential between PV-and ground to above zero through integrated PID recovery function to recover module degradation from PID. Supported module types include: P-type (mono, poly),
N-type (nPERT, HIT)
Subject to modifications.