0 item(s)

Inverter HUAWEI SUN2000-50KTL-M3

50 kw three-phase inverter

The high system voltage and two MPP trackers


SKU: SUN2000-50KTL-M3
5135 €2,618.85 VAT included

Availability: Backorder

Delivery time: 15-20 days

Quantity:

50 kW On-grid invertеr

The HUAWEI SUN2000-50KTL-M3 is known for its high efficiency, reliable performance, and advanced safety features. It has a maximum efficiency of 98.6%, and its smart cooling system ensures optimal performance even in high-temperature environments. It also has built-in surge protection and ground fault detection to ensure safe and reliable operation.

Benefits

 

The inverter offers a wide range of benefits for solar project developers and owners. These include improved energy yield, reduced maintenance costs, and easy installation and commissioning. Its modular design also allows for flexible configuration and expansion as needed.

Specifications:

The HUAWEI 50KTL has a maximum input voltage of 1100V and a maximum output power of 50 kW. It is compatible with both monocrystalline and polycrystalline solar panels, and it can be installed both indoors and outdoors.

Conclusion:

The HUAWEI SUN2000-50KTL-M3 is an excellent choice for large-scale solar projects that require high efficiency, reliability, and safety. With its advanced features, flexible configuration, and easy installation, it is sure to provide long-term value and performance.

Technical Data


 

EFFICIENCY

 
Max. Efficiency 98.50%
European Efficiency 98.00%

INPUT DATA

 
Max. Input Voltage 1 1,100 V
Max. Current per MPPT 30 A
Max. Short Circuit Current per MPPT 40 A
Start Voltage 200 V
MPPT Operating Voltage Range 2 200 V ~ 1,000 V
Rated Input Voltage 600 V
Number of MPP trackers 8
Max. input number per MPP tracker 4

OUTPUT DATA

 
Rated AC Active Power 50,000 W
Max. AC Apparent Power 55,000 VA
Rated Output Voltage 400Vac/480Vac,3W+(N) +PE
Rated AC Grid Frequency 50 Hz / 60 Hz
Rated Output Current 72,2 A
Max. Output Current 79,8 A
Adjustable Power Factor Range  0.8 leading... 0.8 lagging
Max. Total Harmonic Distortion  <3%

PROTECTIONS

 
Input-side Disconnection Device Yes
Anti-islanding Protection Yes
AC Overcurrent Protection Yes
DC Reverse-polarity Protection Yes
PV-array String Fault Monitoring Yes
DC Surge Arrester Type II
AC Surge Arrester Type II
DC Insulation Resistance Detection Yes
Residual Current Monitoring Unit Yes
Communication  
Display LED indicators; Integrated WLAN + FusionSolarAPP
RS485 Yes
Monitoring BUS (MBUS) Yes (isolation transformer required)

GENERAL DATA

 
Dimensions
(height x width x depth)
640 x 530 x 270 mm
Weight 49 kg
Degree of protection IP 66
Night time consumption < 5.5 W
Inverter design Transformerless
Cooling Natural Convection
Installation Indoor and outdoor installation
Ambient temperature range -25°C to +60°C
Permitted humidity 0 % to 100 %
Max, altitude 4000 m
DC connection technology Staubli MC4
AC connection technology Waterproof PG Terminal + OT/DT Terminal
Certificates
Grid Code
EN 62109-1/-2, IEC 62109-1/-2, EN 50530, IEC 62116, IEC 60068, IEC 61683
IEC 61727, VDE-AR-N4105, VDE 0126-1-1, BDEW, G59/3, UTE C 15-712-1, CEI 0-16, CEI 0-21, RD 661, RD 1699,
P.O. 12.3,RD 413, EN-50438-Turkey, EN-50438-Ireland, C10/11, MEA, Resolution No.7,
NRS 097-2-1, AS/NZS 4777.2, DEWA

1. The maximum input voltage is the upper limit of the DC voltage. Any higher input DC voltage would probably damage inverter.
2. Any DC input voltage beyond the operating voltage range may result in inverter improper operating.
     SUN2000-30~40KTL-M3 raises potential between PV-and ground to above zero through integrated PID recovery function to recover module degradation from PID. Supported module types include: P-type (mono, poly),
N-type (nPERT, HIT)


Subject to modifications.

View FileТехнически данни / Datasheet    File size: (387.77 KB)